Strong Acid Cation Exchange Resin,Gel Structure 001x4

阅读:次
1. Indexes of physical and chemical properties:
Designation |
001 x 4 Na/H |
Total Exchange Capacity meq/g≥ |
4.5 |
Volume Exchange Capacity meq/ml≥ |
1.4/ 1.25 |
Water Retention % |
55-65/ 58-65 |
Bulk Density g/ml |
0.75-0.85/ 0.72-0.78 |
Special Density g/ml |
1.12-1.20 |
Particle Size % |
(0.315-1.25mm)≥95 |
Effect Size mm |
0.40-0.60 |
Homogeneous Coefficient ≤ |
1.6 |
Roundness after Wearing %≥ |
90 |
Appearance |
brownish yellow to brown |
Ionic Form Supplied: |
Na/H |
2. Reference Indexes for Operation:
1) PH Range: 1-14
2) Max. Operating Temp (℃): H+≤100℃ Na+≤120℃
3) Total Reversible Swelling %: (Na+→H+) 10-15
4) Working Exchange Capacity: 25℃≥ 1000mmol/l (wet)
5) Concentration of Regenerate Solution: NaCl: 8-10% ; HCl: 4-5%
6) Consumption of Regenerate: NaCl(8-10%)Vol.:ResinVol.=1.5-2:1
HCl(4-5%) Vol.:ResinVol. = 2-3:1
7) Flow Rate of Regenerate Solution: 4-6(m/hr)
8) Regenerate Contact time : 30-60(minute)
9) Rinse Flow Rate: 10-20(m/hr)
10) Rinse Time (minute): 30 (approx.)
11) Operating Flow Rate: 10-40(m/hr)
3.Application:
This product is mainly used for softening hard water and preparing pure and high purity water.
4.International Equivalents:
Amberlite IR-118 (American)
5.Packing: Each PE lined with plastic bag, net weight: 25 L